<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-17 03-33-07
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
6.3 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 66 kHz 11632 15,8184
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,08 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 66 kHz MIN: 12 kHz % above 76 kHz: 15,8184 Acquired: 2025/01/17 3.32.03 Total samples: 11632 Equivalent time: 0:09:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 6,0 dBr MIN: 3,9 dBr AVE: 5,08 dBr % above 12,2 dBr: 0,0 Last value: 4,9 dBr (2025/01/17 3.32.03) 03.18 03.20 03.22 03.24 03.26 03.28 03.30 03.32 0 2 4 6 Pm [dBr]